mULTIMATE 142 LPR & Datalogger details

 
 

HOME

 

TEAM AND MANAGEMENT

 

quality management

 

SERVICES

 

PRODUCTS

 

SITE MAP

 

 

CONTACTS

 

 

 

 

 

One for two functions of corrosion monitoring

Operating principle

LPR measurement: relies on the measuremet of the electrical resistance of the corroding electrode-electrolyte interface. The polarization resistance is measured as the ratio of the applied DC potential to the flowing current and is constant over a small range (<20mV).

The mULTIMATE 142LPR performs a convergent autorange algorithm that can found quickly the best scale of measure.

A single mULTIMATE 142LPR can be used to measure an unlimited number of probes installed at different locations of a system or systems: Each Probe can be distinguished by a unique TAG number  & alphanumeric 10 characters description and measures are memorised in a non-volatile memory.

The mULTIMATE 142LPR is simple to operate: just set TAG number push the Measure key: the instrument will give a corrosion rate reading and automatically memorises data; can collect data from Field Unit’s; can upload setting to Field Unit’s, or can up-load data to Terminal PC acting as a portable datalogger.


Specifications

TWO fuctions in one instrument.

Capable of interrogating and storing data from both data loggers and to make direct measurement from LPR probes, data up-load directly to computer.

LCD display: alphanumeric 16 characters /2 lines

Direct digital readout of corrosion rates with AUTOMATIC scale selection

Direct digital readout of Pitting Index with full automated operations

Direct digital readout of Polarization Potential (mV) 

Set Mode: Auto (timed measuring with autostore) or Man (key-press measuring)

Fully programmable Cycle interval from 1 for minute to 1 for week in steps of 1 minuts

Software controlled, menu driven, readings of the probe upon simple operator commands

Set Point of: Year, Month, Day, Hour, Minute, TAG number (real time clock included)

Set Display out: micron or  micron/y or mils/y.

Set excitation current: Anodic or Cathodic

Mode mULTIMATE Terminal for Upload/Download & exchange data with other  devices

Built- in non-volatile memory (30-Year retaining) up to 3000 Reading measures

PC RS232 connectivity (Software & cable communication included)

Hardware & software compatible with Better Manufacturer’s equipment

Power supply: eight standard AA 1.2V DC rechargeable Ni/Mh batteries

Automatic shutdown feature

Battery duration: 14 hours continuous operating or 1000 measures or 200days in autostore.

Battery charger: 220V AC –50 Hz (110V AC-60 Hz) included

Size: 200x110x70 mm

Weight: 0,5 Kg

Connecting cable: 1.5 mt in coil form.

Package: shockproof polystyrene box in vinyl carrying case.

Complete with carrying case and all necessary leads.